Tuesday, 19 November 2019
Friday, 1 November 2019
vRealize Operations Manager 7.5 - Part9 - Dashboard sharing
Ability to share dashboards using URLs without login requirements is a very useful feature starting from vROps 7.0.
- Select the dashboard that you want to share and click on the share icon as marked in the screenshot below.
- Click on "COPY LINK" and provide it to whoever necessary. You can also set link expiry to 1 Day, 1 Week, 1 Month, 3 Months, or Never Expire as per your requirement.
- To unshare a link, enter the link that you want to unshare as shown below and click "UNSHARE".
Hope it was useful. Cheers!
Related posts
vRealize Operations Manager 7.5 - Part8 - Super Metrics
vRealize Operations Manager 7.5 - Part7 - vSAN monitoring and troubleshooting
vRealize Operations Manager 7.5 - Part6 - Adding new symptoms and alert definitions
vRealize Operations Manager 7.5 - Part5 - Alerting
vRealize Operations Manager 7.5 - Part4 - High availability
Wednesday, 23 October 2019
Docker 101 - Part4 - Creating images using dockerfile
In this article, I will briefly explain how to create your own image using Dockerfile. For example, I will be creating an FIO image. FIO is a storage stress test tool and this image can be used for container storage IO benchmarking/ testing.
- Login to the CentOS docker host.
- Create a file named "Dockerfile".
- # vi Dockerfile
- Add the below two lines and save it.
- Once the build is complete, it returns the IMAGE ID as shown below.
- You can use the "docker tag" command to mention a repository and tag to the image.
- At this stage, as shown in the above screenshot, the FIO image is created with repository "vineethac/fio_image" and tagged as "latest".
- You can run this image as given below.
- # docker run -dit --name FIO_test01 --mount source=disk_data,target=/vol vineethac/fio_image fio --name=RandomReadTest1 --readwrite=randread --rwmixwrite=0 --bs=4k --invalidate=1 --direct=1 --filename=/vol/newfile --size=10g --time_based --runtime=300 --ioengine=libaio --numjobs=2 --iodepth=1 --norandommap --randrepeat=0 --exitall
- The above command will start a container with FIO application running inside it. FIO will use "/vol/newfile" for IO tests. "/vol" is using "disk_data" directory which is inside "/var/lib/docker/volumes". Once the test is complete, the container will exit.
Hope it was useful. Cheers!
Related posts
Docker 101 - Part3 - Persisting data using volumes
Docker 101 - Part2 - Basic operations
Docker 101 - Part1 - Installation
Docker 101 - Part3 - Persisting data using volumes
In this article, I will explain how to use Docker volumes for persisting data generated by and used by containers with --mount flag. Volumes use the Docker area and it can be found under /var/lib/docker/volumes/ directory of the Docker host.
docker run -dit --name centos_volume_test --mount source=data_volume01,target=/datavol01 centos sleep 1800
The above command will run a CentOS container and mounts a volume at /datavol01 inside the container. It uses source /var/lib/docker/volumes/data_volume01. The below screenshot shows the necessary steps to verify it.
Hope it was useful. Cheers!
Related posts
Docker 101 - Part2 - Basic operations
Docker 101 - Part1 - Installation
References
Friday, 18 October 2019
Docker 101 - Part2 - Basic operations
In this article, I will walk you through basic Docker commands and how to work with it for creating, managing, and monitoring Docker containers.
Docker version and info
#docker version
#docker info
Default directory for Docker
#cd /var/lib/docker
Pull images
#docker pull centos:latest
List images
#docker images
Create bridge network
#docker network create -d bridge --subnet 10.0.0.0/24 ps-bridge
List all bridge networks
#brctl show
Inspect a network
#docker run -dt --name centos_test --network ps-bridge centos sleep 900
SSH into a container
#docker exec -it <name> sh
List running containers
#docker ps
List all containers
#docker ps -a
List container stats
#docker stats
Stop a container
#docker stop <Container ID>
Remove a container
#docker rm <Container ID>
Remove an image
#docker rmi <REPOSITORY:TAG>
Hope it was useful. Cheers!
Related posts
References
Docker 101 - Part1 - Installation
Enter cloud native! In this article, I will briefly explain how to build a virtual Docker host. Here I am installing Docker on a CentOS 7.4 virtual machine running on ESXi 6.5 which is part of a VMware vSAN cluster.
Prerequisites:
- Deploy a basic CentOS 7.4 VM
- Assign IP address and ensure the VM has internet connectivity
- You should have root creds
Installation:
- SSH to the CentOS VM as root
- yum check-update
- yum install -y yum-utils device-mapper-persistent-data lvm2
- yum-config-manager --add-repo https://download.docker.com/linux/centos/docker-ce.repo
- yum install docker-ce
- systemctl start docker
- systemctl enable docker
- systemctl status docker
Verify version:
- docker version
Run your first container:
- docker run hello-world
Hope it was useful. Cheers! In the next part, I will explain basic Docker commands and operations.
Related posts
References
Wednesday, 9 October 2019
vRealize Operations Manager 7.5 - Part8 - Super Metrics
In this article, I will briefly explain about using super metrics in vROps 7.5. For example, I will take the VM NUMA optimization super metric which was released recently. You can download the super metric JSON file from the VMware sample exchange.
Once the JSON file is downloaded, login to your vROps instance. Navigate to Administration - Configuration and select Super Metrics. Click on Import Super Metric.
Browse and select the JSON super metric file that you downloaded. Click DONE.
Once it is done, you can see the two super metrics.
Select the super metric - Edit Selected Super Metric - Goto Enable in a Policy - Select vSphere Solution's Default Policy and click FINISH.
Now after the default collection interval, you can see the super metric tab as shown below.
As you can see in the above screenshot, for this virtual machine "lustre01", recommendations are:
- NUMA optimal CPU socket: 1
- NUMA optimal CPU cores per socket: 8
Hope it was useful. Cheers!
References
Related posts
Monday, 7 October 2019
VMware PowerCLI 101 - Part5 - Real time storage IOPS and latency
It is very important to monitor and analyze the performance of storage subsystem components as it direcly affects the application performance. In this article, I will briefly explain how to use PowerCLI to get real time storage IOPS and latency of the following:
- Virtual disk
- Datastore
- Disk/ LUN
- Storage adapter
- Storage path
Connect-VIServer <IP address of vCenter>
To understand the list of all available stats for a specific entity, you can use Get-StatType. For example, to list all real time stats for a virtual machine you can use:
Get-StatType -Entity <VM name> -Realtime | sortVirtual disk
To get real-time IOPS and latency of all virtual disks of a VM named 'lustre01':
Get-Stat -Entity lustre01 -Realtime -MaxSamples 1 -Stat virtualDisk.numberReadAveraged.average,virtualDisk.numberWriteAveraged.average,virtualDisk.totalReadLatency.average,virtualDisk.totalWriteLatency.average | sort Instance,MetricId | select MetricId, Value, Unit, Instance
Datastore
To get real-time IOPS and latency of a datastore (with Uuid: 5bea72bb-5d72ed6a-1d85-246e96792988) from an ESXi host (IP: 192.168.105.10):
Get-Stat -Entity 192.168.105.10 -Stat datastore.numberReadAveraged.average,datastore.numberWriteAveraged.average,datastore.totalReadLatency.average,datastore.totalWriteLatency.average -Realtime -MaxSamples 1 -Instance 5bea72bb-5d72ed6a-1d85-246e96792988 | Select MetricId, Value, Unit, Instance | Sort-Object MetricId
Note: You can get Uuid of a datastore using (Get-Datastore vol01).ExtensionData.Info.Vmfs.Uuid
Refer my article "Real time VMware datastore performance monitoring using PowerShell" for monitoring the real time performance statistics of multiple shared VMFS datastores which are part of a multi-node VMware ESXi cluster.
Disk/ LUN
To get real-time IOPS and latency of a disk (eui.387de1af35b93f6ff0a9bef000000000):
Get-Stat -Entity 192.168.105.10 -Disk -Realtime -Instance eui.387de1af35b93f6ff0a9bef000000000 -MaxSamples 1 -Stat disk.numberWriteAveraged.average,disk.numberReadAveraged.average,disk.totalWriteLatency.average,disk.totalReadLatency.average | Select MetricId, Value, Unit, Instance
Storage adapter
To get real-time IOPS and latency of a storage adapter:
Get-Stat -Entity 192.168.105.10 -Realtime -MaxSamples 1 -Stat storageAdapter.totalReadLatency.average, storageAdapter.totalWriteLatency.average, storageAdapter.numberReadAveraged.average, storageAdapter.numberWriteAveraged.average -Instance vmhba64 | Select-Object MetricId, Value, Unit, Instance | Sort-Object MetricId
Storage Path
To get real-time IOPS and latency of a storage path:
Get-Stat -Entity 192.168.105.10 -Realtime -MaxSamples 1 -Stat storagePath.totalReadLatency.average, storagePath.totalWriteLatency.average, storagePath.numberReadAveraged.average, storagePath.numberWriteAveraged.average -Instance fc.300fb123ba76519c:b436362bae5b217-fc.300fb123ba76519c:b436362bae5b217-eui.387de1af35b93f6ff0a9beec00000001 | Select MetricId,Value,Unit,Instance | Sort-Object MetricId
Labels:
cluster,
datastore,
disk,
ESXI,
IOPS,
latency,
lun,
monitoring,
performance,
PowerCLI,
Powershell,
read,
real time,
real-time,
storage adapter,
storage path,
vCenter,
VMware,
write
Thursday, 19 September 2019
vRealize Operations Manager 7.5 Blog Series
vRealize Operations Manager 7.5 - Part2 - Configure vCenter adapter and dashboards overview
Wednesday, 18 September 2019
vRealize Operations Manager 7.5 - Part7 - vSAN monitoring and troubleshooting
In this article, I will walk you through how to use vROps for vSAN monitoring and performance troubleshooting. It is always recommended to follow a systematic and established approach to troubleshoot problems. Before we start here is a link to one of my article which explains the scientific method of troubleshooting.
Given below are some very useful content from VMware that talks about vSAN performance troubleshooting.
Performance Troubleshooting – Understanding the Different Levels of vSAN Performance Metrics
Performance Troubleshooting – Which vSAN Performance Metrics Should be Looked at First?
Troubleshooting vSAN performance
Performance is all relative and sometimes performance issues can be because of the wrong perception. So it is always good to validate it with actual numbers. Compare with a benchmark value or verify all relevant metrics before and after the issue has been reported. Now assume there is a storage issue in the environment. Given below is a systematic order to approach the problem, identify it correctly, isolate it and finally take necessary steps to resolve it.
- Infrastructure: Perform vSAN cluster health check
- Virtual machine level: Is there a storage issue observed at the application level?
- Virtual machine level: Is there a storage issue per vmdk level?
- Latency (vmdk)
- IOPS (vmdk)
- Cluster level: Look at operations overview at the cluster level
- Latency
- IOPS
- Host level: Identify the IO type that has a performance issue
- Read IO
- Write IO
- Host level: Collect/ analyze metrics of the storage objects
- Storage adapter (vmhba)
- Disk groups
- Cache disk
- Capacity disk
- Host level: Collect/ analyze metrics of the network objects
- Physical adapter (vmnic)
- vSAN network (vmk)
At this point, you have a clearly defined workflow in identifying and resolving the issue. So let's have a look at the various vROps dashboards that provides you end to end visibility of your stack and helps you easily identify and isolate the issue. If there is a problem or abnormality or unusual performance behavior in your vSAN environment, vROps will notify that with alerts based on various metric values it monitors using its inbuilt intelligence and analytics capabilities. Alert generation is based on symptom and alert definitions and this will finally affect the health, risk or efficiency badge of the respective object. Status of the badges, symptoms, alerts, recommendations, historical performance data and time stamps will be very useful in the process of troubleshooting and quickly finding the actual problem.
Infrastructure: Perform vSAN cluster health check
As a starting point, you can make use of integrated health checks from vCenter to verify your vSAN infrastructure.
To understand in-depth about vSAN health checks refer: https://vxplanet.com/2019/01/30/vsan-health-checks-explained-part-1/
Now to get a high-level overview, let's have a look into the health, risk and efficiency badges of vSAN cluster in vROps. Please refer to this blog article from VMware to get a detailed understanding of badges.
Health badge
![]() |
Alerts
Virtual machine level: Is there a storage issue observed at the application level?
You can make use of application aware operations feature in vROps 7.5 to get full stack visibility. Given below are the list of applications that can be currently monitored using vROps 7.5.
You can make use of application aware operations feature in vROps 7.5 to get full stack visibility. Given below are the list of applications that can be currently monitored using vROps 7.5.
Reference to application aware monitoring: https://blogs.vmware.com/management/2019/05/application-aware-operations-with-vrealize-operations-7-5.html
If your application is not supported or if application aware monitoring is not configured, then you can go with native application performance counters/ methods to identify whether the application itself is observing/ affected by storage latency, low IOPS, etc.
Virtual machine level: Is there a storage issue per vmdk level?
If your application is not supported or if application aware monitoring is not configured, then you can go with native application performance counters/ methods to identify whether the application itself is observing/ affected by storage latency, low IOPS, etc.
As a first step, you can use the "Troubleshoot a VM" dashboard to understand and track resource usage of a virtual machine.
![]() |
| Troubleshoot a VM - a |
![]() |
| Troubleshoot a VM - b |
Cluster level: Look at operations overview at the cluster level
vSAN operations overview dashboard
Troubleshooting vSAN dashboard
![]() |
| Troubleshooting vSAN - a |
![]() |
| Troubleshooting vSAN - b |
![]() |
| Troubleshooting vSAN - c |
Host level: Identify the IO type that has a performance issue
Host level storage metrics
Host level: Collect/ analyze metrics of the storage objects
Metrics related to a disk group
Read cache and write buffer metrics of a disk group
Performance metrics of a capacity disk
Host level: Collect/ analyze metrics of the network objects
Metrics related to vmnic (physical NIC) and vSAN vmk
Metrics related to network objects will help to determine whether the performance issue is due to resource contention, network misconfiguration, hardware issue, etc.
Hope it was useful. Cheers!
Related posts:
Related posts:
References:
Labels:
alerts,
cache,
capacity tier,
cluster,
datastore,
Infrastructure,
IOPS,
latency,
monitoring,
storage,
symptoms,
troubleshooting,
VCSA,
virtualization,
vmk,
vmnic,
VMware,
vRealize Operations Manager,
vrops,
vSAN
Subscribe to: